HAPAX ECOPACK SERIES ONLINE UPS

1 – 2 – 3 kVA 1/1 PHASE
6 – 10 kVA    1/1 PHASE

Online Mode Efficiency 92%
Eco Mode Efficiency 97%
Input Power Factor 99%
Power Factor 0,9 90%
DSP Power Factor Controlled True Double-Conversion
Total Cost of Ownership
Compact Design & Small Footprint
Wide Input Range
Easy Installation, Plug & Play
Hapax UPS Ecopack Online

HAPAX ECOPACK SERIES ONLINE Uninterruptible Power Supplies

are designed to provide high efficiency and maximum reliability in different load conditions. 

It is an ideal product for Home&Small Office, Emergency Lighting and Small Server Room Applications with its High Input & Output Power Factor and High Efficiency. 

Its Plug&Play type structure makes the installations simple and quick which can also be configured with external battery sets for longer back up time requirements. Optional additional charger provides shorter re-charging time even with high capacity batteries.

Along its technical performance, HAPAX ECOPACK SERIES ONLINE UPS also offers an attractive price & value for your applications where you need reliable UPS products  from 1kVA up to 10kVA capacity.

HAPAX ECOPACK SERIES ONLINE SINGLE PHASE UPS

Standard Electrical Features 

– Short Circuit & Overload Protection 
– User Friendly LCD Display
– High Input Power Factor
– Cold Start
– Auto Sensing Frequency
– Advanced Battery Management
– Output Power Factor 0.9
– RS232 Communication Port
– Wide Input Voltage Range

Optional Electrical Features 

– Input & Output Voltage Selection
– Can work with 50Hz and 60Hz Grids
– Power-On Self Test
– Output bypass can be adjusted by the LCD panel
– Automatic Charging in Off Mode
– Auto Control Fan Speed when Loads Varies
– Monitoring And Shutdown Software
– SNMP, Dry Contact, Modbus Communications

Technical Specifications

 

1 -2 – 3 kVA 

MODEL

1 – 2 – 3 kVA 1/1 Phase

Capacity

1000VA

2000VA

3000VA

Power Watt

900W

1800W

2700W

INPUT

 

Nominal Voltage

208V / 220V / 230V / 240 VAC

Voltage Range

110 ~ 176 VAC (Linear Derating Between 50% and 100% load); 176 ~ 280 VAC (No Derating); 280 ~ 300 VAC (Derating 50%)

Frequency

40 ~ 70 Hz (Auto Sensing)

Power Factor

>0.99

Bypass Voltage Range

-25% ~ +15% (Settable)

OUTPUT

 

Voltage Range

208V / 220V / 230V / 240 VAC (Settable via LCD)

Voltage Regulation

±1%

Frequency

45 ~ 55 Hz or 55 ~ 65 Hz (Synchronized Range); 50 / 60 Hz ±0.1 Hz (Battery Mode)

Waveform

Sinusoidal

Output THD

≤2% (Linear Load); ≤5% (Non-Linear Load)

Crest Factor

3:1

Transfer time

Mains Mode to Battery Mode: 0ms

Inverter Mode to Bypass Mode: 4ms (Typical)

Overload Capability

105% ~ 125%: Transfer to Bypass in 1min

125% ~ 150%: Transfer to Bypass in 30s

>150%: Transfer to Bypass in 300ms

Efficiency (Online)

≥90%

≥91%

≥92%

Efficiency (Eco Mode)

≥95%

≥96%

≥97%

BATTERY

 

DC Voltage

24 V

36 V

36 V

48 V

72 V

72 V

72 V

96 V

96 V

Inbuilt Battery

2 x 7Ah

3 x 7Ah

External

4 x 7Ah

6 x 7Ah

External

6 x 7Ah

8 x 7Ah

External

Max. Charging Current

1A

6A

1A

6A

1A

6A

Recharge Time

8 hours

GENERAL

 

Running Temperature

For UPS 0°C/+40°C ; For Battery +15°C/+25°C

Storage Temperature

For UPS -15°C/+45°C ; For Battery 0°C/+30°C

Alarms

Utility Failure, Low Battery, Overload, UPS Fault

Humidity

0-90% Without Condensation

Noise Level

≤45 dB (1m)

Communication Port

Standard: RS232,  ;   Optional: SNMP, Dry Contact, EPO, USB

Communication

Supports Windows®98/2000/2003/XP/Vista/2008/Windows®7/8/10

DIMENSIONS & WEIGHT

1000VA

2000VA

3000VA

UPS Dimension wxdxh mm

144 x 336

x 214

144 x 414

x 214

144 x 336

x 214

191 x 418 x 335

191 x 464

x 335

191 x 418

x 335

Packaging Dimension

Wxdxh mm

232 x 417

x 318

231 x 492

x 316

232 x 417

x 318

318 x 533 x 471

320 x 573

x 471

318 x 533

x 471

Net Weight – kg

9.5

13

6

18

25.7

10.5

27.2

32

11

Package Weight -kg

10,5

14,2

7

19,5

27,4

12

29

34

12,5

 

6 – 10 kVA

 

MODEL

6 – 10 kVA 1/1 Phase

Capacity

6000VA

10000VA

Power Watt

5400W

9000W

INPUT

 

Nominal Voltage

208V / 220V / 230V / 240 VAC

Voltage Range

Half Load (110-300) ±5 VAC, Full Load (160-300) ±5 VAC

Frequency

40 ~ 70 Hz (Auto Sensing)

Power Factor

>0.99

Bypass Voltage Range

160V – Rated Output Voltage +32V

OUTPUT

 

Voltage Range

208V / 220V / 230V / 240 VAC (Settable via LCD)

Voltage Regulation

±1%

Frequency

45 ~ 55 Hz or 55 ~ 65 Hz (Synchronized Range); 50 / 60 Hz ±0.1 Hz (Battery Mode)

Waveform

Pure Sine Wave

Output THD

≤2% (Linear Load); ≤5% (Non-Linear Load)

Crest Factor

3:1

Transfer time

AC Mode to Battery Mode: 0ms

Inverter Mode to Bypass Mode: 0ms

Overload Capability

105% ~ 125%: Transfer to Bypass after 3min

125% ~ 150%: Transfer to Bypass after 30sec

>150%: Transfer to Bypass after 100ms

Efficiency (Online)

≥92%

Efficiency (Eco Mode)

≥98%

BATTERY

 

DC Voltage

192V-240V

Inbuilt Battery

16 x 9Ah

20x 9Ah

Max. Charging Current

Standard: 1A  / Optional: 1A, 3,5A, 7A

Recharge Time

8 hours up to 90% Capacity

GENERAL

 

Running Temperature

For UPS 0°C/+40°C ; For Battery +15°C/+25°C

Storage Temperature

For UPS -15°C/+45°C ; For Battery 0°C/+30°C

Alarms

Utility Failure, Low Battery, Overload, UPS Fault

Humidity

20-90% Without Condensation

Noise Level

≤50 dB (1m)

Communication Port

Standard: RS232,  ;   Optional: SNMP, Dry Contact, EPO, USB

Communication

Supports Windows®98/2000/2003/XP/Vista/2008/Windows®7/8/10

DIMENSIONS & WEIGHT

6000VA

10000VA

UPS Dimension wxdxh mm

262 x 650 x 735

Packaging Dimension

Wxdxh mm

440 x 720 x 940

Net Weight – kg

64

71

Package Weight -kg

72

79

* Product pictures are for represantational purpose. The color, size, weight or design of the actual product may vary.
Elektra Power Solutions Kft. reserves the right to change or modify product design, construction, specifications, or materials without prior notice.

HAPAX ECOPACK SERIES SINGLE PHASE ONLINE UPS

Elektra Power Solutions Kft.

1062 Budapest, Bajza utca 68. 2/2. Hungary

+36 70 254 07 85

info@elektrapower.hu